FLUTEC™ TG-TRACERS are fully-fluorinated, odourless,
colourless, non-volatile liquids. They are ideal candidates for tracing
and tagging applications:
- Detectable at parts per Quadrillion levels
- Negligible Background concentrations
- Non-flammable
- Compatible with most construction materials.
- Non-toxic
- Excellent Chemical and thermal stability
- Non-radioactive
- Non-corrosive
There are twelve FLUTEC™ TG-TRACERS in the range, with boiling
points between, 45oC and 155oC allowing multi-tracer
experiments to be performed, FLUTEC™ TG-TRACERS can be deployed,
sampled, and analysed with the same instrumentation simultaneously
Although FLUTEC™ TG-TRACERS are considered biologically
and chemically inert, good laboratory practice should be observed
when handling. FLUTEC™ TG-TRACERS have an indefinite shelf
life if properly stored in their original sealed containers
|
Flutec TG-Tracer
|
PMCP
|
PMCH
|
o-PDMCH
|
p-PDMCH
|
m-PDMCH
|
PECH
|
PFIND |
PTMCH
|
i-PPCH
|
n-PPCH
|
PFD
|
PFMD
|
| Material Safety Data Sheet |
View |
View |
View |
View |
View |
View |
View |
View |
View |
View |
View |
View |
|
Formula
|
C6F12
|
C7F14
|
C8F16
|
C8F16
|
C8F16
|
C8F16
|
C9F16 |
C9F18
|
C9F18
|
C9F18
|
C10F18
|
C11F20
|
|
Molecular Weight
|
300
|
350
|
400
|
400
|
400
|
400
|
412 |
450
|
450
|
450
|
462
|
512
|
|
Boiling Point,
oC
|
48
|
76
|
102
|
102
|
102
|
102
|
120 |
127
|
130
|
130
|
142
|
155
|
|
Melting Point,
oC
|
-70
|
-30
|
-70
|
-70
|
-70
|
-70
|
<-20 |
-68
|
<-20
|
<-20
|
-8
|
-70
|
|
Vapour pressure
Mbar
|
368
|
141
|
48
|
48
|
48
|
29
|
23.7 |
9.6
|
10
|
10
|
8.8
|
2.9
|
|
Viscosity
mPa s
|
1.049
|
1.561
|
-
|
-
|
1.919
|
1.714
|
3.6 |
2.275
|
-
|
-
|
5.10
|
6.41
|
|
Critical temp., oC
|
180.8
|
212.8
|
241
|
241
|
241.5
|
235.1
|
273 |
121
|
-
|
-
|
29.2
|
313.4
|
|